Contactor CTX3 3P 18A 1NO1NC 230V AC
- P/N: 416106
- EAN: 3414970399960
- Rating: 18A (AC – 3) switching of 3 – Phs motors up to 7.5kW(415V).
- Resistance Load: Up to 40A (AC – 1).
- Screw terminal capacity: Power – 2 x 1.5mm2 to 10mm 2 / Coil – 0.75mm2 to 2.5mm2 / Aux.circuit – 0.75mm2 to 2.5mm2.
- 1NO + 1NC auxiliary contacts.
- According to IEC 60947 – 4 – 1 standards and can be equipped with all Legrand CTX3 auxiliaries and accessories.
- Endurance: Up to 15million mechanical operations and 2.5 million electrical operations.
- of operation cycle: (AC – 3) / Hr: 1800
Reccomendation/Restriction
- This product is specifically designed for tertiary & Industrial installation.
- To use for the switching of inductive and non inductive loads.
TECHNICAL CHARACTERISTICS
Rated control supply voltage AC 50 HZ | 195.5-253 V |
Rated control supply voltage AC 60 HZ | 195.5-253 V |
Voltage type for actuating | AC |
No.of normally closed contact as main contact | 0 |
No.of normally opened contact as main contact | 3 |
Type of electrical connection of main circuit | Cable clamp |
Rated operation current le at AC-1, 400V | 32A |
Rated operation current le at AC-3, 400V | 18A |
Rated operation power at AC-3, 400V | 7.5kW |
Rated operation current le at AC-4, 400V | 11A |
Rated operation power at AC-4, 400V | 4kW |
No.of auxiliary contact as normally opened contact | 1 |
No.of auxiliary contact as normally closed contact | 1 |
Suitable for distribution board | Yes |
Product’s Benefits
Installation
It can be fixing on 35mm ‘top hat” mounting rail (IEC 60715) and mounting plate.Reduced size to optimize the space available in the cabinet.
Usage
It can be fitted with 1NO+1NC auxiliary contact, factory assembled. Designed to allow an easy replacement of the coil.
Advantage
Coil supply possible either on the top or the bottom side.
Rated control supply voltage AC 50 HZ | 195.5-253 V |
Rated control supply voltage AC 60 HZ | 195.5-253 V |
Voltage type for actuating | AC |
No.of normally closed contact as main contact | 0 |
No.of normally opened contact as main contact | 3 |
Type of electrical connection of main circuit | Cable clamp |
Rated operation current le at AC-1, 400V | 25A |
Rated operation current le at AC-3, 400V | 12A |
Rated operation power at AC-3, 400V | 5.5kW |
Rated operation current le at AC-4, 400V | 9A |
Rated operation power at AC-4, 400V | 4kW |
No.of auxiliary contact as normally opened contact | 1 |
No.of auxiliary contact as normally closed contact | 1 |
Suitable for distribution board | Yes |
Product’s Benefits
Installation
It can be fixing on 35mm ‘top hat” mounting rail (IEC 60715) and mounting plate.Reduced size to optimize the space available in the cabinet.
Usage
It can be fitted with 1NO+1NC auxiliary contact, factory assembled. Designed to allow an easy replacement of the coil.
Advantage
Coil supply possible either on the top or the bottom side.